Ttd Voltage Electrical Insulation Piercing Clamps for ABC Cable

Product Details
Certification: RoHS, ISO, CE
Color: Black
Surface Treatment: Electroplating
Still deciding? Get samples of US$ 0/Piece
Request Sample
Manufacturer/Factory, Trading Company
Gold Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001
  • Ttd Voltage Electrical Insulation Piercing Clamps for ABC Cable
  • Ttd Voltage Electrical Insulation Piercing Clamps for ABC Cable
  • Ttd Voltage Electrical Insulation Piercing Clamps for ABC Cable
  • Ttd Voltage Electrical Insulation Piercing Clamps for ABC Cable
  • Ttd Voltage Electrical Insulation Piercing Clamps for ABC Cable
  • Ttd Voltage Electrical Insulation Piercing Clamps for ABC Cable
Find Similar Products
  • Overview
  • Product Description
  • Products Catalogue
  • Company Profile
  • FAQ
Overview

Basic Info.

Usage
Over-Voltage Protection
Material
Silicone Rubber & Zinc Oxide
Type
Ttd Series
Gender
Male
Rated Voltage
33kv
Standard
IEC60099-4
Mounting Plate
Include
OEM Production
Accept
Transport Package
Wooden Case
Specification
Customized
Trademark
EP
Origin
Hebei, China
HS Code
85369090
Production Capacity
100000piece/Pieces Per Month

Product Description


Ttd Voltage Electrical Insulation Piercing Clamps for ABC Cable
Product Description
TTD Insulation Piercing Clamps for ABC Cable
 
Equivalent type
Main Line Section
Branch Section
(mm²)
Norminal Current(A)
Bolt
Torque nut
Number
H(mm)
TTD041FJ
6-35
1.5-10
86
1×M8
13
F1309
TTD051FJ
16-95
1.5-10
86
1×M8
13
F1309
TTD101FJ
6-50
2.5(6)-35
200
1×M8
13
F1314
TTD151FJ
25-95
2.5(6)-35
200
1×M8
13
F1314
TTD201FJ
35-95
25-95
377
1×M8
13
F1318
TTD251FJ
50-150
25-95
377
1×M8
13
F1318
TTD271FJ
35-120
35-120
377
1×M8
13
F1318
TTD281FJ
50-185
2.5(6)-35
200
1×M8
13
F1314
TTD301FJ
25-95
25-95
377
2×M8
13
F1314
TTD401FJ
50-185
50-150
504
2×M8
13
F1318
TTD431FJ
70-240
16-95
377
2×M10
17
F1720
TTD441FJ
95-240
50-150
504
2×M10
17
F1725
TTD451FJ
95-240
95-240
530
2×M10
17
F1725
TTD551FJ
120-400
95-240
679
2×M10
17
F1737
The insulation piercing connectors are applicable for all types of LV-ABC conductors as well as connections in service line systems, building electrical systems,s and street lighting systems. Insulation-piercing connectors can be easily done by tightening the bolts to force the teeth to penetrate the insulation of the main line and tap line simultaneously. Stripping of insulation is avoided for both lines.
  1. Main line: Insulated aluminum cable
  2. Tap line: Insulated aluminum cable or Insulated copper cable
  3. The body is molded from tough and weather-resistant materials
  4. Special designed shear head bolt allows efficient installation under controlled shear torque which ensure the contact teeth properly penetrate the conductor without damaging the mechanical strength of the conductor
  5. Tested for watertightness at the voltage of 6kV for 1min under water
  6. Safe live-line installation
  7. Seals and grease are applied to prevent moisture entering the cable and connector which guarantees excellent waterproof and corrosion resistant performance
  8. End cap is attached to the body. No loose parts could fall to ground during installation 
  9. Standard: EN 50483-4, NFC 33-020, NFC 33-004  
Ttd Voltage Electrical Insulation Piercing Clamps for ABC CableMechanical performance:the grip force of the wire clamp is 1/10 bigger than the break fore of the lead,t comply with GB2314 -1997.
Temperature rise performance:under the condition of big current,the temperature rise of connector is less than that of connection lead.
Heat circle performance:conforms to GB/T2317.3- -2000,the heat circle trial standard for electric ftting.
Waterproof insulation performance:conforms to the relevant testing requirements in Part2 of GB/T13140.4- -1998.
Resistance to corrosion performance:under the condition of So2 and salt fog.it can do three times of fourteen days circletesting.
Environmental aging performance:under the circumstance of utraviolet,radiation,dry and moist,expose it with change of temperature and heat impulse for six weeks.
Fire proof promamce.insulation material of the cnnector wthtands glowing flament tst.ontorom 1o the rquirements inChapter4-10 of GB/T5169.4.
Ttd Voltage Electrical Insulation Piercing Clamps for ABC Cable
Type
Conductor Range(mm²)
Norminal Current(A)
Piercing Depth(mm)
Bolt Size(mm)
Bolt Size(mm)
Main
Branch
EP101
1.5-2.5
1.5-10
75
1-2
M6X55
10
POWERTEK
16-95
1.5-10
75
1-2
M6X55
10
EP2-95
16-95
4-35(50)
132
2.5-3.5
M8X70
20
EP3-95
25-95
25-95
214
1.5-2
M8X70
20
Ttd Voltage Electrical Insulation Piercing Clamps for ABC CableTtd Voltage Electrical Insulation Piercing Clamps for ABC Cable
Piercing connector, simple installation, need not strip the cable coat
Moment nut, piercing pressure is constant, keep good electric connection and make no damage to lead

Ttd Voltage Electrical Insulation Piercing Clamps for ABC Cable

The insulation piercing connectors are applicable for all types of LV-ABC conductors as well as connections in service line systems, building electrical systems,s and street lighting systems.
A combination of easy installation with excellent mechanical, electrical and environmental characteristics provides a connector capable of terminating aluminum or copper-stranded conductors.
 
Ttd Voltage Electrical Insulation Piercing Clamps for ABC Cable
Ttd Voltage Electrical Insulation Piercing Clamps for ABC Cable
Products Catalogue

 

Ttd Voltage Electrical Insulation Piercing Clamps for ABC Cable
Company Profile
Ttd Voltage Electrical Insulation Piercing Clamps for ABC CableTtd Voltage Electrical Insulation Piercing Clamps for ABC Cable

 

FAQ

1. Q: Do you provide sample service?
A: Yes, we only provide samples and ask for one piece at a time. The freight should be borne by you.

2. Q: Do you support customized services?
A: Yes, we can customize the size and logo according to your needs. Please consult the customer service for the specific minimum order quantity.

3. Q:  How is the Design & Engineering?
A:  Experienced and skilled team of designers including CAD designers and 3D designers has the capacity to deliver outstanding designs for your project. If you require more complex engineering of structures such as overhead transmission and distribution lines design,we can also provide this service also designer fee . 

4. Q:  What's the payment term? 
A:  We accept T/T, L/C, West Union.

5. Q:  What's the delivery time? 
A:  Usually within 7-15 days according to quantities 

6. Q:  What's the standard of package? 
A:  Export standard package or special package as the requirement of customers. 

7. Q:  What kind of product quality your factory offer? 
A:  Our products with both excellent quality and competitive price. And we offer free sample for your reference. 

8. Q:  What kind of certificate you have? 
A:  We have ISO9001:2008

Ttd Voltage Electrical Insulation Piercing Clamps for ABC Cable

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now